Promhub Logo promhub_

NodeRAIDDegraded
critical

Description RAID array '{{ $labels.device }}' on {{ $labels.instance }} is in degraded state due to one or more disks failures. Number of spare drives is insufficient to fix issue automatically.
Query for 15m
>>>
	
				
					node_md_disks_required
				
			
				
					 - ignoring (state) (
				
			
				
					node_md_disks
				
			
				
					{state="active"}) > 0

				
			
    
Query Explanation

The query subtracts the number of currently active disks from the total disks required for each RAID device (ignoring the state label); if the result is greater than 0, it indicates that required disks are missing or failed and there aren't enough spare drives, which triggers the NodeRAIDDegraded alert.